Prove e Misure

Grazie ad un laboratorio molto attrezzato, siamo in grado di offrire un servizio di misure elettriche e ambientali a chiunque desideri validare i propri prodotti, in particolare per quanto riguarda le prove ambientali possiamo eseguirle in accordo ai seguenti standard:

Prove di temperatura e umidità

  • CEI EN 60068-2-1 (Freddo)
  • CEI EN 60068-2-2 (Calore secco)
  • CEI EN 60068-2-14 (Cambio di temperatura)
  • CEI EN 60068-2-30 (Caldo umido ciclico)
  • CEI EN 60068-2-78 (Caldo umido stazionario)
  • DO160F , paragrafo 4,5 e 6 (Altitudine 0ft)

Prove di vibrazione e shock (combinate con camera climatica)

  • MIL-STD 810G – United States Department of Defense
  • MIL 167 – Military Standard, mech. vibrations of shipboard equipment
  • NAVMAT P-9492 – Temperature Cycling and Random Vibration
  • NASA-HDBK-7005, 2001 Dynamic Environmental Criteria, NASA Technical Handbook
  • NASA-HDBK-7004, 2003 Force Limited Vibration Testing, NASA Technical Handbook
  • ASTM D999 – Vibration testing of shipping containers
  • ASTM D3580 – Vibration (vertical sinusoidal motion) test of products
  • ASTM D4728 – Random Vibration testing of shipping containers
  • ISO 2247 – Vibration test at fixed low frequency
  • ISO 8318 – Vibration tests using a sinusoidal variable frequency
  • ISO 9022-10 – Combined sinusoidal Vibration, dry heat or cold
  • ISO 9022-15 – Combined random vibration wide band: reproducibility medium, dry heat or cold
  • ISO 9022-19 – Temperature cycles combined with sinusoidal or random vibration
  • ISO 16750-3 – Automotive electronics
  • IEC 60068-2-64 – Environmental Testing: Part II, methods, vibration, broad-band random
  • EIA-RS-186 – Passive electronic component parts- Method 8- Vibration, High Frequency
  • JIS C0040 – Environ. Tests Part II: Tests, Test Fc and Guidance: Vibration (sinusoidal)
  • 22-A11B-HAST
  • ETS 300 019-2-0 – Telecom equipment transportation
  • RTCA DO-160 – Radio Technical Commission for Aeronautics (RTCA) publishes DO-160, Environmental Conditions and Test Procedures for Airborne Equipment

Il sistema vibrante

Caratteristiche tecniche sistema temperature/umidità/shock

  • Temperatura: da -75°C a +180°C
  • Umidità relativa: da 5% a 98 %
  • Gradiente max di temp.: 15°C/min
  • Volume area di prova = 610 litri (850x740x970 mm)
  • Forza applicabile : 8KN
  • Tipi di prove: Sinusoidale, Random, Sine on Random, Shock
  • Escursione massima : 50mm
  • Shock massimo : 180G (<=7 ms)